Hua-style Box-type Substation
The Hua-style transformer substation is structurally different from both American-style and European-style transformer substations. It features a unique R-type high-voltage connection and independently structured units, with separate transformer compartments, high-voltage switchgear compartments, and low-voltage switchgear compartments, which are connected by wires to form a complete power supply system. With its rational design, easy installation, and simple operation, it avoids the limitations of American-style transformer substations and has significant cost advantages compared to wind (photovoltaic) European-style transformer substations. It is applicable to new energy generation sites with broad prospects.
- Overview
- Recommended Products
Product Overview:
The Hua-style transformer substation is structurally different from both American-style and European-style transformer substations. It features a unique R-type high-voltage connection and independently structured units, with separate transformer compartments, high-voltage switchgear compartments, and low-voltage switchgear compartments, which are connected by wires to form a complete power supply system. With its rational design, easy installation, and simple operation, it avoids the limitations of American-style transformer substations and has significant cost advantages compared to wind (photovoltaic) European-style transformer substations. It is applicable to new energy generation sites with broad prospects.
Specifications and Parameters:
Application: |
Wind power generation |
Photovoltaic power generation |
AC input (AC): |
Project actual value |
Project actual value |
AC boosting (AC): |
35KV~38.5KV |
35KV~38.5KV |
High-voltage switchgear circuit breaker: |
Assembled vacuum circuit breaker |
Assembled vacuum circuit breaker |
Transformer: |
S18 series |
S18 series |
Dimensions: |
Customized |
Customized |
Product Features:
Comparison of American, European, and Hua-style Transformer Substations
Comparison Item |
American-style Transformer Substation |
European-style Transformer Substation |
Hua-style Transformer Substation |
Maintenance and inspection, oil refueling |
Required (serious defect) |
Not required |
Not required |
Maintenance and inspection, system shutdown |
Not required |
Required (serious defect) |
Not required |
Impact of solar exposure on power generation |
Yes (defect) |
No |
No |
Arc-extinguishing switch impact on pollution |
Yes (defect) |
No |
No |
Reduced power generation due to system shutdown |
No |
Yes (defect) |
No |
Transformer fan heat dissipation |
Not required |
Required (defect) |
Not required |
Enclosure insulation protection |
No (defect) |
Yes |
Yes |
Weather impact on maintenance |
Yes (defect) |
No |
No |
Cost |
Slightly low |
Slightly high |
Slightly high |